How to convert tons to kW. One refrigeration ton is equal to 3.5168525 kilowatts: 1 RT = 3.5168525 kW. One kilowatt is equal to 0.284345 refrigeration ton: 1 kW = 0.28434517 RT . So the power P in kilowatts (kW) is equal to the power P in refrigeration tons (RT) times 3.5168525: P (kW) = P (RT) × 3.5168525 . Example. Convert 2 RT to kilowatts
power in watts. The conversion from EER to kW/ton is shown below. 1 ' ' 4 L 1 $ P Q D 1 9 = P P ∗ 1 P K J 12,000 $ P Q D ∗ 1 0.001 L 1 P K J 12 G 9 SEER: The Seasonal Energy Efficiency Ratio or SEER is similar to EER 2.0 DISCLAIMER In no event will Engineering Pro Guides be liable for …
water using less than 0.50 kW per ton of cooling capac-ity. A refrigeration system must also reject the heat that it removes using a cooling tower for water cooling the condenser (most efficient) or using fans for air cooling the hot refrigerant of the condenser coil.
W = boiler capacity (Btu/h, kW) h g = enthalpy steam (Btu/lb, kJ/kg) h f = enthalpy condensate (Btu/lb, kJ/kg) m = steam evaporated (lb/h, kg/s) Boiler Horsepower - BHP. The Boiler Horsepower (BHP) is. the amount of energy required to produce 34.5 pounds of steam per hour at a pressure and temperature of 0 Psig and 212 o F, with feedwater at 0
Clayton Industries is an industrial steam boiler manufacturer of fired steam generators and fluid heater steam generators. Clayton's industrial process steam boilers are available in 18 sizes from 15 to 2000 Boiler Horsepower (150 to 20,000 kW) and 518 to 69,000 pounds of steam per hour (235 to 37,300 kg/hr).
How to Convert Kilowatts to Amps. For a single phase AC circuit the formula to convert kilowatts (kW) to amps is: amps = (kW × 1,000) ÷ volts. It is possible to find the amperage from kilowatts if you know the voltage of the circuit using Watt's law. Watt's Law states that current = power ÷ voltage. In Watt's Law, power is measured in
Convert Boiler horsepower to Kilowatts (bhp → kW)
How to Convert MBH to Kilowatt. 1 MBH = 0.2930710702 kW 1 kW = 3.4121416331 MBH. Example: convert 15 MBH to kW: 15 MBH = 15 × 0.2930710702 kW = 4.3960660526 kW…
1 Boiler horsepower = 9.8095 Kilowatts: 10 Boiler horsepower = 98.095 Kilowatts: 2500 Boiler horsepower = 24523.75 Kilowatts: 2 Boiler horsepower = 19.619 Kilowatts: 20 Boiler horsepower = 196.19 Kilowatts: 5000 Boiler horsepower = 49047.5 Kilowatts: 3 Boiler horsepower = 29.4285 Kilowatts: 30 Boiler horsepower = 294.29 Kilowatts: 10000 Boiler horsepower = 98095 Kilowatts: 4 Boiler …
Horizontal and vertical boilers/water heaters use electrical current to generate hot water and steam — all electrical energy is converted to heat. With automatic controls, each boiler is simple to operate and maintain. Types: Cleaver-Brooks Electrode, Models S, CR, WB, HSB and IWH.
The ton (ton of refrigeration) is a unit of power. This tool converts tons to kilowatts (ton to kw) and vice versa. 1 ton ≈ 3.5169 kilowatts. The user must fill one of …
CONVERSION OF BOILER IN KG/H AND KW (Approximate) G.B. and U.S.A. Steam from and at 100°C Boiler HP Kg/h 2.26MJ/kg Metric System Steam from 0°C to 100°C Kg/h 2.26MJ/kg Power In kW 1 5 10 15 20 30 40 50 60 70 80 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 15.65 78 156 235 313 470 626 783 940 1096 1252 1566 2350 3130 3915 4700
33.475 BTU / hr (9,811 kilowatts) to generate 1 hp. Unfortunately, the common practice is to use the conversion factor of 34.5 lb / hr hp to calculate the boiler generated steam rate without considering that the boiler does not work at atmospheric pressure. ex. 500 hp x 34.5 lb / hp hr = 17,250 lb / hr produced by the boiler.
Kilowatts to tons of refrigeration (RT) conversion calculator
Steam Boiler Steam Steam Boiler Manufacturer WNS 0.5 Ton Steam Boiler For Rice Mill. Up to 5 years warranty Automatic Control Level Exported to Pakistan WNS Gas Oil Boiler 500KW 1000 KW. US $5000-$85000 / Unit. 1 Unit (Min Order) 10 YRS Henan Horizontal Natural Circulation 500 Liter Boiler. US $15500-$68600 / Set. 1.0 Sets (Min Order) 2
The Kabola HR series consists of reliable oil-fired boilers that provide 10, 14 and 20kW. HR series is either available as boiler, with heating boiler control and ad combi boiler. Because of its whisper-quiet, fully automatic operation, this boiler can be used for many purposes. HR series is especially suitable for longterm- or permanent use on
Click for easy access to results in different languages
Click for easy access to results in different languages
300-600 ft 2 /ton: Ton: 12,000 BTU/ton: Chilled Water: 2.4 GPM/ton (10° rise) Condenser Water: 3 GPM/ton (10° rise) Chiller Input: Air Cooled Chillers: 1 kW/ton. Water Cooled Chillers: 0.6 kW/ton. Most Efficient Water Cooled Chillers: 0.35 kW/ton: Chillers & Pumps & Towers.9-1.0 kW/ton: Absorbers: 18 lbs steam/ton: Boiler Horsepower: 33,479
Boiler Rating in kW to kg/hr. Boiler Rating kW kW. Boiler Pressure P bar g . Latent Heat of Evaporation at Above Pressure hfg kCal/kg . Calculate. Boiler Steam Output m s kg/hr of Steam Navigation. Heat Loss Calculation (Surface upto 200 deg. C) Boiler Blowdown Calculation; Dryer Efficiency for Textile Industry;